0-20mA/4-20mA/0-10V Signal Generator Adjustable Current Voltage Analog Current Signal Source
Malipo Salama Yanahakikishiwa

Zawadi ya Bure
Karibu Roymall, tovuti yako ya kitaalamu ya kununua zawadi za hifadhi ya duka. Tunathamini na kushukuru msaada wako, na tunataka kuonyesha shukrani yetu kwa kuongeza kipengele cha msisimko wa ziada kwa ununuzi wako. Unaponunua nasi, sio tu utapata bidhaa za hali ya juu zinazoboresha maisha yako, lakini utapata pia zawadi ya bure ya kipekee kwa kila agizo lako. Tayari kuchunguza mkusanyiko wetu na kupata zawadi zako kamili? Chunguza uteuzi wetu wa bidhaa za hifadhi ya duka, weka agizo lako na subiri msisimko wa zawadi yako ya bure kufika pamoja na ununuzi wako.Sera ya Usafirishaji
Tutafanya kazi kwa bidii kukufikishia bidhaa baada ya kupokea maagizo yako na kuhakikisha zinafika salama. Maelezo ya uwasilishaji yatakuwemo kwenye barua pepe yako ya uthibitisho.Kwa hali ya kawaida, maagizo huchakatwa ndani ya siku 2. Katika hali maalum, yanaweza kucheleweshwa kama ifuatavyo: Unapoagiza Jumamosi, Jumapili au siku za likizo, itacheleweshwa kwa siku 2.Kwa kawaida, inahitaji siku 5-7 za kazi (Jumatatu hadi Ijumaa) bila kuathiriwa na ucheleweshaji wa ndege au mazingira mengine.Kwa sababu huduma yetu ya usafirishaji ni kimataifa, muda wa uwasilishaji utategemea eneo lako, kwa hivyo inaweza kuchukua muda na tafadhali subiri kwa subira ikiwa uko katika wilaya au nchi za mbali.1. Sera ya Kurudisha na Kubadilisha
Tunakubali tu bidhaa zilizonunuliwa kutoka roymall.com. Ikiwa unanunua kutoka kwa wasambazaji wetu wa ndani au wauzaji wengine, huwezi kuzirudisha kwetu. Bidhaa za mauzo ya mwisho au zawadi za bure hazikubaliki kwa kurudisha.Ili kuwa na haki ya kurudisha, bidhaa yako lazima isitumike na iwe katika hali ileile uliyoipeleka. Pia lazima iwe kwenye pakiti ya asili.Baada ya kupokea maagizo ya kurudisha kutoka kwetu, tafadhali pakiti bidhaa zako zilizorudishwa na kuacha kifurushi chako kwenye ofisi ya posta ya ndani au mtoa huduma mwingine wa usafirishaji.Tutachakata bidhaa yako ya kurudisha au kubadilisha ndani ya siku 3-5 za kazi baada ya kuipokea. Rudi pesa itachakatwa na kuwekwa kiotomatiki kwenye njia yako ya awali ya malipo.Hakuna kurudisha au kubadilisha kunaweza kukubaliwa ikiwa bidhaa ilitengenezwa kwa maagizo maalum, ikiwa ni pamoja na saizi maalum, rangi maalum au uchapishaji maalum.Ikiwa unahitaji msaada zaidi, tafadhali wasiliana nasi. service@roymall.com au Whatsapp: +8619359849471
2. Sera ya Kurudisha Pesa
Utapata rudi pesa kamili au stoo 100% ya stoo baada ya kupokea na kukagua kifurushi kilichorudishwa. Rudi pesa itachakatwa kiotomatiki kwenye njia yako ya awali ya malipo.Tafadhali kumbuka kuwa gharama za usafirishaji na ushuru wowote au ada hazirudishiwi. Gharama za ziada za usafirishaji hazirudishiwi mara tu kifurushi kimetumwa. Wewe ndiye mwenye jukumu la kulipa ada hizi na hatuwezi kuziacha au kuzirudisha, hata kama agizo litarudishwa kwetu.Mara tu tutakapopokea na kuthibitisha bidhaa yako iliyorudishwa, tutakutumia barua pepe kukujulisha kuwa tumepokea bidhaa yako. Pia tutakujulisha kuhusu uthibitisho au kukataliwa kwa rudi pesa yako.Ikiwa una shida yoyote kuhusu mchakato wa kurudisha pesa, tafadhali wasiliana nasi. service@roymall.com au Whatsapp: +8619359849471Parameters:
Supply voltage: 24VDCVoltage output: 0-10V adjustable, drive current <20mACurrent output: 0-22mA adjustable, load sampling resistance <500 ohmsAdjustment resolution: 0.1V/0.01V or 0.1mA/0.01mALinearity: better than 0.2%Display mode: 4-digit digital tubeAdjustment method: rotary encoder + keyTerminal interface definition:24v: positive pole of power supply0V: negative pole of power supplyACOM: voltage and current signal output negative poleAout+: Current signal output positive poleVout+: voltage signal output positive poleParameter settings and usage1. Switch voltage/current mode: Click the Display button to switch the current voltage/current mode, the current output value is digitally displayed, rotate the encoder to change the output value, press the encoder to reset and restore the output value;2. How to enter the menu mode: long press the rotary encoder, the screen will display ----, at this time the rotary encoder rotates once each time; in voltage mode, the order is right, left, left, left, and right, the screen will display rLLr, if the password is correct, the menu interface will be automatically entered. P001; In current mode, the order is right, left, left, and the screen displays rLrL. If the password is correct, the menu interface will automatically enter and P001 will be displayed;3. Save and exit: When the "POOX" interface is currently displayed, long pressing the encoder will save and exit to the main interface;4. Exit without saving: When the "POOX" interface is currently displayed, enter the parameter adjustment mode and long press the encoder to exit to the main interface without saving;
Features:
1. Versatile Output Range: The Signal Generator boasts an adjustable voltage output range of 0-10V and a current output range of 0-22mA, allowing for a wide range of applications. With a drive current of less than 20mA and a load sampling resistor of less than 500u03a9, this generator is perfect for a variety of uses.2. Precise Adjustment: The Signal Generator features an adjustment resolution of 0.1V /0.01V or 0.1mA/0.01mA, ensuring precise and accurate signal generation. The rotary encoder + button adjustment method allows for easy and intuitive use.
3. Excellent Linearity: With a linearity of better than 0.2%, the Signal Generator provides consistent and accurate signal generation. Users can rely on this generator for precise and reliable results.
4. User-Friendly Display: The Signal Generator features a 4-digit digital tube display for easy and clear reading of output values. This user-friendly display makes it simple to monitor and adjust the generator"s output.
5. High-Quality Design: The Signal Generator is designed with high-quality materials and components, ensuring long-lasting and reliable performance. Its compact and durable design makes it easy to use and transport, making it an ideal choice for both laboratory and field use.
Signal generator operating instructions
Parameter | illustrate | Remark | Default value |
P001 | model | 0: Coarse adjustment 1: Fine adjustment | 0 |
P002 | Voltage range | 0: 0-10V 1: 0-5V 2: 0~3V 3: 0-2.5V | 0 |
P003 | Coarse resolution | Adjust resolution = 0.1V x current display value | 01 |
P004 | Fine-tune resolution | Adjust resolution = 0.01V x current display value | 01 |
P005 | 10V calibration | Rotate the encoder until 10V and then press the rotary encoder to confirm | 4015 |
P006 | 0.03V calibration | Rotate the encoder until it reaches 0.03V and then press the rotary encoder to confirm. | 18 |
P007 | Save after power off | 0: Off 1: On (stable and saved for 600s) | 0 |
Current menu
Parameter | illustrate | Remark | Default value |
P001 | model | 0: Coarse adjustment 1: Fine adjustment | 0 |
P002 | Current range | 4: 0-20mA 5: 4-20mA 6: 0-22mA 7: 4-22mA | 4 |
P003 | Coarse resolution | Adjustment resolution = 0.1mA x current display value | 01 |
P004 | Fine-tune resolution | Adjustment resolution = 0.01mA x current display value | 01 |
P005 | 20mA calibration | Rotate the encoder until 20mA and then press the rotary encoder to confirm | 3702 |
P006 | 0.1mA calibration | Rotate the encoder until it reaches 0.1mA and then press the rotary encoder to confirm. | 8 |
P007 | Save when current is cut off | 0: Off 1: On (stable and saved for 600s) | 0 |
Package Include: